The YubiKey device can be reset to a factory state. This is useful of the organization desires to reuse the YubiKey.

Step Number

Procedure

Example

1

Log in to the IDMS

Go to PIV/Manage and retrieve the user that encoded the YubiKey,


2

Click the Credentials Tab

In the Credentials table, locate the user, click the Action button and select Terminate.

This process will revoke the credentials that are on the YubiKey

image2021-7-8_11-3-25.png

image2020-6-11_11-42-0.png

3

Next, press the cancel request button to remove any issuance requests for the YubiKey

image2021-7-8_11-4-50.png

image2020-6-11_11-42-8.png

4

Next, press the Delete device button to remove the YubiKey device association with the user.

image2021-7-8_11-6-16.png

5

Next click Reports, Devices, press Read Device

image2021-7-8_11-8-9.png

image2021-7-8_11-8-38.png

6

Next, press Reset Device to remove any card management keys from the IDMS.

image2021-7-8_11-9-11.png

7

Finally, use the YubiKey utility to restore the device to factory settings.

image2020-6-11_11-42-17.png